Performance data
Maximum performance – minimum water consumption
- Water spray durations and frequencies are automatically adjusted by the controller in order to optimise the performance and minimise water consumption.
- The higher the ambient temperature, the greater the frequency and duration of the spray to match the ambient conditions.
Once the lower ambient set point is reached the spray operation is automatically terminated.
- Through intermittent spray operation and set point limits, water consumption can be minimised by as much as 75% in comparison to a comparable cooling tower, evaporative or any other adiabatic cooling unit.
Air cooled chillers

- Any make or model of air cooled chiller, whether a new unit or retrofit application can be converted to an EcoMESH wet system by means of either a factory add on or on site modification.
- To calculate the efficiency improvements available to air cooled chillers click here.
Air cooled condensers
- Air cooled condensers and Dry Coolers can be either horizontal, vertical “V” or “W” configuration and EcoMESH can be fitted in any type of orientation for a new unit or retrofit application. Note: some condenser manufacturers are able to offer EcoMESH as a factory fitted option.
EcoMESH has been successfully installed to a large number of ammonia air cooled condensers achieving maintenance and legionella free operation.
- Significant compressor improvements are achievable. To request a copy of the compressor efficiency improvements available to air cooled condensers click here.
Unitary Products
Unitary products such as Rooftop and Mini Split units rely on dry bulb only.
- By simply fitting an EcoMESH kit to convert the dry bulb to a wet bulb ambient operation the condenser output of the unit can be increased by as much as 40%.
- Multiple units can be controlled from a single controller for a cost effective and easy set-up site installation for both new and retro fit applications.
Dry Coolers
Any make or model of Dry Cooler, whether a new project or retrofit application, can be converted to a wet system by means of either factory add on or on site modification.
- To calculate the efficiency improvements available to dry cooled chillers click here.
Air Inlet Cooling
For air inlet cooling systems EcoMESH is placed within the airstream.
- This provides the benefits of a wet bulb temperature system providing a practical, cost effective and safe adiabatic air cooling system.
To calculate the system improvements and energy savings click here
For more technical information on EcoMESH click here